Short answer: put your modem (or fiber box) and router on the battery-backed outlets of a UPS, along with any mesh node or switch your connection runs through. Then check the UPS maker’s runtime figures against what that equipment draws. That keeps your side running. If the outage also affects your provider’s network, your connection can still drop, so a phone hotspot is a useful fallback.
What has to stay powered
Your connection passes through every box between the incoming line and your device. List the ones in your home:
- the modem, or the fiber box your provider installed
- the router
- any mesh nodes or extenders you rely on
- any switch between the router and your devices
What your provider has to offer
If you get home phone service from your internet provider, ask what backup power it offers. In a public notice dated November 27, 2018, the FCC reminded facilities-based providers of fixed home voice service that isn’t line-powered that, from February 13, 2019, they must offer for sale at least one backup-power option with a minimum of 24 hours of standby power for the equipment in the home. That followed a 2015 order requiring an 8-hour option.
According to that notice, those providers must also tell you, when you sign up and every year after, whether backup power is available and what service works with and without it during an outage. They must also say how long the backup is expected to last and how to test and monitor it.
The rule is about voice service. The notice doesn’t say a provider’s backup must keep your internet running, so ask your provider what its battery powers.
Setting up a UPS for your network
- Use the battery outlets. On some UPS units, not every outlet is battery-backed. APC lists one of its Back-UPS models as having “7 NEMA outlets (2 surge)”. Check the labels on your unit and plug the network equipment into the battery side.
- Check runtime against your load. Look up two things on the UPS maker’s product page: its watt rating and its runtime figures for different loads. For the load, add up the power ratings printed on your modem and router adapters; treat that total as a cautious estimate rather than an exact draw. Keep lamps, TVs and computers off the battery outlets so the network gets the runtime.
- If it reports an overload, APC’s troubleshooting for its Back-UPS ES models BE600M1, BN650M1 and BN675M1 says to remove everything that isn’t essential and reconnect devices one at a time.
- Look after the battery. For those same models, APC says runtime falls as the battery ages, and a fully drained battery needs about ten hours on AC power to recharge. A rapidly flashing green power button means about two minutes of runtime are left.
When the outage is bigger than your house
For a longer-term second connection, including routers that switch over automatically, see backup internet for working from home.